General description
Starting with version 3.15, each time the desktop client is launched the settings are loaded from the ClientSettings file for subsequent migration into the client. The ClientSettings file must be placed in the profile directory:
- Windows —
%APPDATA%\VinteoDesktop; - macOS —
$HOME/Library/Application Support/VinteoDesktop; - Linux —
$HOME/.config/VinteoDesktop.
Settings in the ClientSettings file are stored in JSON format and are validated by a JSON schema when the file is read.
The full list of settings available for migration is provided in Client settings (settings).
The ClientSettings file has the following groups of settings:
- profile — corporate profile settings;
- settings — application settings;
- emailInvitationTemplate — email invitation template.
Migrated settings parameters
Each setting in a group is an object with two properties:
| Property | Description |
|---|---|
| value | The setting value that will be migrated to the application. Type is string, number, or boolean depending on the setting |
| overwriteUserSettings | Optional forced migration flag. When true, the value from the file overwrites the user’s setting in the client. When false or omitted, the setting is overwritten only if the user has not changed it since the first client launch |
Client settings (settings)
The settings group contains the following settings:
| Setting | Value type | Description |
|---|---|---|
| displayName | string | User display name |
| remoteMicControl | boolean | Allow the moderator to turn the microphone on and off |
| remoteCameraControl | boolean | Allow the moderator to turn the camera on and off |
| moveContentVideoToFullscreen | boolean | Open an incoming presentation in full-screen mode |
| autoOpenChat | boolean | Automatically open chat when starting a call or broadcast |
| autoOpenParticipants | boolean | Automatically open the participant list when starting a call or broadcast |
| autoAnswer | boolean | Auto-answer for an incoming call |
| autoMute | boolean | Mute the microphone on auto-answer |
| autoFullscreen | boolean | Full-screen mode on auto-answer |
| hardwareNotification | boolean | Hardware alert |
| autorun | boolean | Auto-start |
| minimizeOnClose | boolean | Minimize the application on close |
| disableConfirms | boolean | Disable all confirmation dialogs |
| disableNotifications | boolean | Turn off all notifications |
| disableErrors | boolean | Turn off all error notifications |
autoOpenChat and autoOpenParticipants are enabled, autoOpenParticipants takes precedence: autoOpenParticipants is enabled and autoOpenChat remains disabled. The order and simultaneity of the flags do not matter.
Corporate profile
The corporate profile is created and updated by migration scripts. It differs from other profiles by a unique UUID: uuid-corporate-profile-0fa76dd5-9c48-48de-be1b-75b8df1b2208. The profile is created if it is not yet in the connection profile list, or updated during migration.
Corporate profile settings (profile)
The profile group contains the following settings available for corporate profile migration:
| Setting | Value type | Description |
|---|---|---|
| name | string | User login. Optional |
| serverUrl | string | Connection server address. May contain a URL or IP |
| profileName | string | Corporate profile name — shown as the connection profile title. Optional |
Each time the corporate profile is rewritten, the password of the previous profile is removed from the client.
In ClientSettings, set the server address in values.profile.serverUrl and the user’s display name in values.settings.displayName. If connection details are missing, the client opens the connection setup dialog at startup. You can skip this step.
Example of setting the display name in ClientSettings
{
"version": 1,
"values": {
"settings": {
"displayName": {
"value": "New signature",
"overwriteUserSettings": true
}
}
}
}Email invitation templates (emailInvitationTemplate)
This option configures the conference invitation template sent by email.
Template parameters
| Name | Value type | Description |
|---|---|---|
| value | TEmailInvitationTemplate | Email invitation template |
| overwriteUserSettings | boolean | Template usage flag. If true, the given template is used for email invitations; otherwise the standard application template is used. Default is false |
Email invitation template (TEmailInvitationTemplate)
| Name | Value type | Description |
|---|---|---|
| subject | string | Invitation title |
| body | TBodyEmailInvitationTemplate | Message body |
Message body (TBodyEmailInvitationTemplate)
| Name | Value type | Description |
|---|---|---|
| value | string | Message text template |
| optional | TOptionalBodyEmailInvitationTemplate | Optional parameters |
Optional parameters (TOptionalBodyEmailInvitationTemplate)
| Name | Value type | Description |
|---|---|---|
| pinText | { textWhenFilled: string; textWhenEmpty: string } | Template for displaying the conference PIN. textWhenFilled is used when the conference has a PIN; otherwise textWhenEmpty is used |
Fillable template fields
| Setting | Value type | Description |
|---|---|---|
| {userName} | string | Name of the user who sent the invitation |
| {conferenceUrl} | string | https link to join the conference |
| {dialedNumber} | string | conference-number@domain |
| {pin} | string | PIN code |
| {pinText} | string | Template for displaying the conference PIN |
Example ClientSettings file:
{
"version": 1,
"values": {
"emailInvitationTemplate": {
"value": {
"subject": "mailto:?subject=Invitation to the conference",
"body": {
"value": "&body={userName} invites you to take part in a video conference.%0A- link: {conferenceUrl};%0A- conference number: {dialedNumber}{pinText}",
"optional": {
"pinText": {
"textWhenFilled": ";%0A- PIN code: {pin}.",
"textWhenEmpty": "."
}
}
}
},
"overwriteUserSettings": false
}
}
}