System settings

Network, access, SIP/H.323, devices, system operations and updates

bg-dots
bg-dots

Terminal on-screen interface → Settings

On the home screen, open Settings → System settings. Use the arrows on the remote to select a section, press OK to open it, and press Back to return.

Network

The terminal can have one or two network interfaces. Configure the interface with the cable connected to the intended network.

IPv4

Enable IPv4 to use it on the selected interface. The “Status” column shows the connection state and current settings. With DHCP enabled, the terminal obtains addressing automatically. To use static addressing, disable DHCP and set the following fields. Enter IPv4 addresses as four numbers from 0 to 255 separated by dots.

IP address assigns the terminal an address on this network.

Subnet mask determines which addresses are on the local network.

Gateway sets the router address for reaching other networks.

DNS server sets the address of the server that resolves domain names to IP addresses.

Press “OK” on a row to enter a value. Select “Save” to apply the settings.

IPv6

Use “Turn on” to enable IPv6 on the selected interface. When the checkbox is clear, “Status” reads “Disabled”. Select “Save” to apply a change.

Modes

Auto enables automatic negotiation of link speed and duplex. For manual configuration, clear the checkbox and select a Speed of 10, 100, or 1000 Mbit/s and a Duplex mode. Full sends and receives data simultaneously. Half alternates transmission directions. Select settings compatible with the equipment at the other end of the link.

MTU

MTU sets the largest IP packet the interface can carry without fragmentation, in bytes. The editor accepts whole numbers from 68 to 1500 bytes. The screenshot shows 1500 bytes. Enter a size supported by the network and select “Save”.

Access

The options under System settings → Access control local access with the remote and network access to the terminal.

“by SSH” – allows SSH connections on any terminal model. Clearing the checkbox disables SSH access. The terminal-specific commands are available only on T and ST. See SSH command console.

“by web” – allows users to sign in to the web interface from a browser. Clear the checkbox to disable browser access.

“RC PIN” – protects access to System settings from the remote. When the checkbox is selected, the terminal prompts for a PIN, masks the characters with asterisks and displays an error if the PIN is incorrect. Clearing the checkbox allows access to system settings without a PIN.

Web password

“Web password” opens an input field and an on-screen keyboard. The specified password length is 6 to 64 characters. “Delete” removes the last character.

Support

“Support” – issues a temporary username and password that a support engineer can use to connect to the terminal over SSH.

Step 1. Open Settings → System settings → Access and select the “Support” checkbox. The “Login and password” dialog opens in the centre of the screen. Keep it open while you enter the credentials on your computer.

Step 2. On a computer, run the following command. Replace <user> with the value shown under “Login” and <address> with the terminal’s IP address.

ssh <user>@<address>

When SSH prompts for a password, enter the value shown under “Password”.

Step 3. After connecting, select “OK” to close the dialog. When the support engineer has finished, clear the “Support” checkbox. The terminal rejects new logins with that pair. The next time you enable support mode, the terminal generates a new username and a new password.

SIP / H.323

Open System settings → SIP / H.323, select a protocol, and press “OK” to expand its settings.

SIP

“Enabled” – allows incoming and outgoing SIP calls. Clear the checkbox to turn off SIP calls.

“Registration” – registers the terminal with the SIP server at the configured address. Clear the checkbox to stop registering with the server.

“Login, pass.” – enables authentication during registration. With the checkbox cleared, the terminal registers without the specified login and password.

Registration server – the SIP server address. Select the row below the checkboxes to change the address.

Registration login – the SIP account name supplied by the server administrator.

Registration password – the password for that account. The entry masks the saved value.

“API-key” – the key for accessing the server address book. Enter the key supplied by the server to use its address book.

H.323

“Enabled” – allows incoming and outgoing H.323 calls. Clear the checkbox to turn off calls over this protocol.

“Registration” – registers the terminal with an H.323 gatekeeper. With the checkbox cleared, the terminal does not register with the gatekeeper.

To register the terminal, enable registration and enter the gatekeeper address. If the gatekeeper requires authentication, select “Login, pass.” and enter the login and password supplied by its administrator.

Device

Audio output

“1 playback device” selects the primary output. The tested terminal offers an ALC887-VD Analog output and an HDMI PL2792Q output.

“2 playback device” selects an additional output from the same devices. Leave it at “Not chosen” if a second output is unused.

The slider below an assigned output sets the volume from 0% at the left to 100% at the right. The HDMI output shown is set to 100%. Select the play icon to the right of the list to play a test sound through that output.

Audio input

“1 audio recorder” selects the primary audio input. The tested terminal offers the two Eco Capture Dual HDMI M.2 inputs (00-00 and 00-01) and the built-in ALC887-VD Analog input.

“2 audio recorder” selects an additional input. Choose “Not chosen” to leave this input unassigned.

The slider below an assigned input sets its recording level from 0% to 100%. The first HDMI input shown is set to 75%. The meter to the right of the list shows the incoming signal level.

Monitor

Open Settings → System settings → Device → Monitor. Each connected monitor appears as a thumbnail with the output name below it, such as DP-1.

Select the thumbnail and press “OK”. The first list sets the resolution in pixels. The second sets the refresh rate in hertz for the selected resolution. Select “Main” to assign this monitor as the primary display.

The list contains nine options. Alongside 1920x1080, it offers 1920x1080i, where i denotes interlaced scan.

At 1920x1080, the choices are 69.9607, 60, 50 and 59.9402 Hz.

The available modes depend on the monitor. The terminal reports the following progressive-scan modes for the display connected to DP-1.

Resolution, pixels Refresh rate, Hz
800 × 600 60.3165
1024 × 768 60.0038
1280 × 720 60, 50, 59.9402
1280 × 1024 60.0197
1440 × 900 59.8874
1600 × 900 60
1680 × 1050 59.9543
1920 × 1080 69.9607, 60, 50, 59.9402

Video inputs

Open Settings → System settings → Device → Video inputs. The right pane shows the available sources. Each card shows the input type and device name above the preview. If a source is not sending video, its preview shows NO SIGNAL.

Select a source card and press “OK” to open its settings. “Main” assigns the source to the primary video stream. “Presentation” assigns it to the content stream. For a local input, select the format, then the frame size and frame rate. Select “Save” to apply the settings.

HDMI

The terminal shown has two Eco Capture Dual HDMI M.2 inputs. On 00-00, “Presentation” is selected. The format is YUYV at 1920 × 1080 and 30 fps. Below the frame rate, VISCA and camera address 1 identify the control protocol and the camera that receives pan, tilt and zoom commands.

Setting Available values
Format YUYV, UYVY, NV12, YV12, YU12, RGB3, RGB4, BGR3, BGR4, GREY, Y16, YUV4
Resolution, pixels 640 × 360, 640 × 480, 720 × 480, 720 × 576, 768 × 576, 800 × 600, 856 × 480, 960 × 540, 1024 × 576, 1024 × 768, 1280 × 720, 1280 × 800, 1280 × 960, 1280 × 1024, 1368 × 768, 1440 × 900, 1600 × 1200, 1920 × 1080, 1920 × 1200, 2048 × 1536
Frame rate at each resolution, fps 1–60

The first list below the role checkboxes selects the format in which the terminal receives video from this input.

In the second list, select the capture resolution in pixels.

The third list sets the capture frame rate in frames per second. The current value is highlighted.

This HDMI input offers VISCA and VISCA over IP for camera control. Select the protocol supported by the camera.

With VISCA selected, a camera address list appears below the protocol. The list uses Russian labels in both interface languages, from “Адрес 1” to “Адрес 7”. Select the address assigned to the camera on the control line.

Input 00-01 has both role checkboxes cleared. Its settings are YUYV, 1920 × 1080, 30 fps, VISCA and camera address 2. Each input has its own capture and camera control settings.

Use VISCA over IP to control a camera over the network. You can set its IP address in the input settings in Web interface → Settings → Video inputs. Open Camera to pan, tilt or zoom.

USB

The card name for the USB UHD CAMERA starts with ImagePlus_UHD_Media. The camera uses MJPG at 1920 × 1080 and 30 fps, with UVC control. It is the main source. The available formats, resolutions and frame rates depend on the USB camera model.

Setting Available values
Format MJPG, H264, HEVC, YUYV
Resolution, pixels 320 × 180, 320 × 240, 352 × 288, 640 × 360, 640 × 480, 704 × 576, 720 × 576, 800 × 600, 1024 × 768, 1280 × 720, 1280 × 960, 1280 × 1024, 1600 × 1200, 1920 × 1080, 2048 × 1536, 2592 × 1944, 3840 × 2160
Frame rate at each resolution, fps 5, 10, 15, 20, 25, 30

The first list below the role checkboxes selects the format in which the terminal receives video from this input.

In the second list, select the capture resolution in pixels.

The third list sets the capture frame rate in frames per second. The current value is highlighted.

This USB camera offers UVC, VISCA and VISCA over IP. The terminal uses UVC to send control commands over USB in the configuration shown.

NDI

In Video inputs, a network camera carries the NDI badge. Select its card and press “OK”. The VINTEO-300-IP-20NDI camera shows two role checkboxes below its name. “Main” assigns it to the primary video stream. “Presentation” assigns it to the content stream. Select “Save” to apply the choice.

Adv. settings

Main

  • “Displaying the Information Bar in a Call” shows terminal status messages over the call.
  • “Use echo cancellation” reduces echo caused by speaker audio being picked up by the microphone.
  • “Rington” plays a ringtone for incoming calls.
  • “Show lecturer on second screen” displays the first conference stream on the second monitor when that monitor is not showing shared content. With this option off, the second monitor displays its standby image in that state.
  • “Allow remote control of your camera” allows incoming FECC commands for a compatible camera.
  • “DTMF input mode - waiting #” holds entered digits until you press #. Clear the checkbox to send digits as you enter them.
  • “Extended remote character entry” lets you cycle through digits and Latin letters by pressing a numeric key repeatedly. Hold # to toggle this mode.
  • “Save status of Vinteo microphones on mute” preserves the state of each daisy-chained Vinteo microphone when it is switched off.
  • “Control all Vinteo microphones with any microphone button” applies a button press on one connected Vinteo microphone to the whole group.

Scroll down to see the remaining settings.

  • “Show watermark” shows participant labels in multipoint calls.
  • “Interface sounds” provides audible feedback for actions in the interface.
  • “P2P mode” limits the terminal to one simultaneous call.
  • “PC mode” shows the HDMI input assigned to content over the home screen on the first monitor after a call or a restart.
  • “Enable tcpdump” allows network traffic capture under Diagnostics in the web interface.
  • “DND in call” hides incoming calls during an active outgoing call. The incoming caller waits until the call times out.
  • “Send presentation audio when microphone is muted” continues to send presentation audio while the microphone is muted.
  • “Automatic audio recording and transcription of calls” automatically records call audio and processes it with the transcription service. Set up the service under Thesis in the web interface.

Terminal

Move the focus to the right, highlight a setting with the arrow keys and press “OK” to open its list. Press “Back” to close the list without selecting a value.

“Default protocol” sets the protocol for new outgoing calls. Choices are SIP and H323.

“Resolution” sets the image dimensions. Choices are CIF 352x288, 640x360, VGA 640x480, 4SIF 704x480, 4CIF 704x576, HD 1280x720 and FullHD 1920x1080.

“Bandwidth” sets the media stream bitrate in kbps. Choose a value the network can support. Values in kbps are 256, 320, 384, 448, 512, 768, 1024, 1536, 2048, 2560, 3072, 3584, 4096, 4608, 5120, 6144, 8192 and 10240.

“FPS main” sets the frame rate for main video. Values are 1, 5, 10, 15, 24, 30 and 60 frames per second.

“FPS presentation” sets the frame rate for shared content. Values are 1, 3, 5, 10, 15, 25 and 30 frames per second.

“Bandwidth mode” selects the Narrow or Wide profile for the connection.

“DTMF mode” controls how key presses are sent to the remote party. RFC 2833 sends key presses as events. Inband sends them as tones.

“Echo cancellation profile” selects an audio processing profile. Profiles 1, 2 and 3 are available.

Vinteo gives approximate delay settings for the WebRTC implementation. Profile 1 uses about 80 ms and keeps the manually set microphone gain. Profile 2 uses about 300 ms and automatic digital gain adjustment for a long acoustic path. Profile 3 uses about 20 ms and adjusts microphone gain adaptively. The documentation identifies it as the standard profile.

“Echo cancellation implementation” switches between WebRTC and Mic AEC. Mic AEC uses hardware echo cancellation on ValueHD SDMIC, Array S1 and M702 microphones. The terminal uses WebRTC for other devices.

“AEC” controls how echo cancellation runs. The options are Automatic mode, Metering mode and Echo cancellation is disabled. The last option turns echo cancellation off.

“SIP Transport” sets the signaling transport. Select the transport configured on your SIP server. The options are UDP, TCP and TLS.

“USB device blocking mode” controls access for USB devices. Allowed all permits any USB device. Audio and video are allowed permits audio and video devices. Everything is prohibited blocks USB devices.

“Receiving remote control commands” selects the source of remote-control commands. Choose Standard IR receiver for the built-in infrared receiver or VISCA / VISCA UDP for commands over VISCA.

Call settings, SIP transport and USB device permissions are also available under Invocations, SIP and Security in the web interface.

Routes

Each row in “IP route definition” shows how the terminal reaches a destination network. The terminal uses the default route when there is no more specific route for the destination address.

  • via gives the gateway address.
  • dev identifies the network interface.
  • proto identifies the route source. For example, static indicates a static route, while kernel indicates a route added by the operating system.
  • scope link identifies a network reachable directly through the interface.
  • src is the terminal’s preferred source IP address for the route.
  • metric sets the preference among routes to the same network. A lower metric takes priority.

Add static routes under NAT in the web interface.

System

Open Settings → System settings → System, move the focus to the right and use the arrow keys to select a command. Press “OK” to activate the selected command.

Turn off

Ends calls and turns the terminal off. Select “Cancel” before the countdown finishes if you started shutdown by mistake.

Restart

Interrupts active calls and starts the terminal again. To stop the restart, select “Cancel” before the countdown finishes.

Reset

Reset restores the terminal to its initial state and opens the setup wizard. It removes settings and audio levels, contacts, call history, added videos, error reports, system reports and conference logs. Licenses are retained. Select “Cancel” before the countdown finishes if you started the reset by mistake.

Update

Opens the update wizard. To install from USB, connect a drive containing the update file under its original name and select the file in the wizard. To install from a server, select “Update via network” and verify the address. Telephony stops when installation starts. Close the wizard before starting installation if you need to postpone the update.

To request a patch under an active support contract, contact support with the organization and a contact phone number.

Create backup

Creates a backup of the terminal configuration so you can restore it later.

Install backup

Restores settings from an existing backup. Restoring replaces the current configuration with the saved configuration.

Uploading logs

Exports terminal logs for troubleshooting.

Main settings Presentation